Dual-Unit Technical Specifications (N4X-WM304)
| Parameter | Engineering Specification | Reference / Notes |
|---|---|---|
| Standard Dimensions (H × W × D) | 400×300×200 mm to 1000×800×300 mm (15.7×11.8×7.9 in to 39.4×31.5×11.8 in) | Custom H/W/D increments available on project drawings |
| Enclosure Alloy & Surface | AISI 304 Stainless Steel (18% Cr / 8% Ni), #4 Brushed (Ra <= 0.8 µm) | Passivated TIG-welded seams ground smooth for washdown cleanability |
| Body & Door Thickness | 16 ga (1.5 mm) up to 600 mm H; 14 ga (2.0 mm) for 800–1000 mm H | Rolled gutter lip around door opening channels liquid away from gasket |
| Roof Geometry | 20° forward-sloped integral roof with 25 mm (1.0 in) front overhang | Prevents water pooling, debris collection, and tool placement on top |
| Door Gasket System | Continuous robot-poured polyurethane (PU) foam-in-place (-40°C to +100°C) | Optional blue FDA-grade silicone gasket (-50°C to +180°C) for hot CIP |
| Latching & Hinges | 316 SS hygienic quarter-turn compression latches + concealed 130° SS hinges | Optional 3-point roller latch on heights >= 800 mm (31.5 in) |
| Internal Mounting Sub-Panel | 12 ga (2.5 mm) galvanized steel sub-panel included on M8 weld studs | Optional 304 stainless or powder-coated white RAL 9010 panel |
| Standards & Documentation | Built to NEMA 250 Type 4X and UL 508A enclosure design requirements | Material mill certificates (304/316L) and ingress test reports available per project |
Target Applications & Operating Fit
- Food, dairy, poultry, beverage bottling, and bakery lines undergoing daily hot alkaline or caustic foam washdowns.
- Pharmaceutical cleanroom and secondary packaging walls requiring smooth brushed #4 stainless surfaces without crevice traps.
- OEM packaging skids, weigh-fillers, and checkweigher control stations needing hygienic wall-mount or pedestal mounting.
- Facilities eliminating water-pooling flat tops to simplify sanitation inspections and reduce premature door-seal wear.
Structural & Standards Engineering
- Continuous TIG-welded corners ground and blended to #4 brushed grain with zero external rivets or exposed fastener threads.
- Integral 20° sloped roof overhangs the front door seam to deflect overhead spray away from the upper gasket interface.
- Formed 90° inward return flange creates a raised perimeter knife-edge that compresses evenly into the poured-in-place PU seal.
- M6 stainless bonding studs welded to both enclosure body and door for compliant protective earth continuity.
5-Parameter Engineering Modification Scope
- Factory fiber-laser pre-cutouts from customer DXF/STEP for HMIs, 22.5 mm pushbuttons, and status beacons.
- Blue FDA-compliant silicone perimeter gasket upgrade for >100°C steam/CIP washdown zones.
- 25 mm or 50 mm stainless wall standoff spacers to allow complete washdown drainage behind the rear panel.
- Bottom-entry removable stainless cable gland plate with EPDM gasket or hygienic stainless cord grips.
- Internal DIN rail kits, sloped sanitary floor pedestal stands, and anti-condensation breather/drain plugs.
Technical FAQs
Why does the N4X-WM304 use a 20° sloped roof instead of a flat top?
Flat-top enclosures trap washdown water, chemical foam, and food residue, which accelerates seam corrosion and creates sanitation audit failures. A 20° forward slope with a front drip overhang forces liquid to shed cleanly past the door seal.
Is AISI 304 sufficient for daily food plant washdowns, or do I need 316L?
AISI 304 handles standard hot water, mild alkaline detergents, and indoor food-processing washdowns effectively. If your sanitation protocol uses high-concentration chlorinated sanitizers, brine, or coastal salt air, specify the N4X-WM316L with 2–3% molybdenum.
What temperature range does the continuous poured polyurethane gasket withstand?
Standard continuous poured-in-place polyurethane (PU) gaskets are rated for -40°C to +100°C (-40°F to +212°F). For continuous high-temperature steam or caustic CIP cycles above 100°C, an optional blue silicone gasket rated to +180°C is available.
Can N4X-WM304 ship with pre-cut HMI and pushbutton holes?
Yes. Submit your DXF or STEP drawing when requesting a 15-minute formal quote, and our fiber-laser line cuts all door and gland openings prior to passivation and gasket dispensing.
Related NEMA 4X Supply Models
304 Free-Standing Washdown Control Cabinet
Floor-standing single-door AISI 304 cabinet (14/12 ga) with 15° sloped roof, 3-point padlockable stainless handle, sanitary leveling feet, and heavy 10 ga sub-panel.